STM 公司
巖棉煙氣治理等離子導(dǎo)濾器項(xiàng)目
技術(shù)協(xié)議
需方:STM 公司
供方:襄陽九鼎昊天環(huán)保設(shè)備有限公司
2020 年 10 月 13 日
2 目 錄
1.總述........................................................................................................................................ 1
2.等離子導(dǎo)濾器設(shè)計(jì)條件........................................................................................................ 1
3.標(biāo)準(zhǔn)和規(guī)范............................................................................................................................ 1
4.等離子導(dǎo)濾器要求 ............................................................................................................... 2
4.1 一般性要求 ................................................................................................................ 2
4.2 等離子導(dǎo)濾器本體配置要求 .................................................................................... 3
4.3 等離子導(dǎo)濾器高壓電源 ........................................................................................... 4
4.4 低壓程控設(shè)備技術(shù)要求 ........................................................................................... 5
4.5 照明 ........................................................................................................................... 6
4.6 檢修電源箱 ................................................................................................................ 6
4.7 在線監(jiān)測(cè)系統(tǒng) ............................................................................................................ 6
5.等離子導(dǎo)濾器技術(shù)數(shù)據(jù)和性能 ........................................................................................... 7
5.1 等離子導(dǎo)濾器選型 .................................................................................................... 7
5.2 等離子導(dǎo)濾器等離子段性能參數(shù)表 ........................................................................ 7
5.3 等離子導(dǎo)濾器導(dǎo)濾段技術(shù)數(shù)據(jù)和性能 .................................................................... 9
6.性能驗(yàn)收試驗(yàn) ..................................................................................................................... 10
6.1.性能驗(yàn)收試驗(yàn) .......................................................................................................... 10
7.供貨范圍及分工 ................................................................................................................. 11
7.1 供貨范圍分界的基本原則 ...................................................................................... 11
7.2 詳細(xì)供貨范圍及分工 .............................................................................................. 12
7.3 備品備件 .................................................................................................................. 14
8.技術(shù)資料和交付進(jìn)度 ......................................................................................................... 15
8.1 技術(shù)資料要求 .......................................................................................................... 15
8.2 配合工程設(shè)計(jì)的資料與圖紙 ................................................................................. 15
8.3 技術(shù)資料范圍 ......................................................................................................... 16
9.施工周期 ............................................................................................................................. 16
10.質(zhì)保 ................................................................................................................................... 16
11.其它 ................................................................................................................................... 16
襄陽九鼎昊天環(huán)保設(shè)備有限公司
XIANGYANG JIUDING HAOTIAN EP EQUIPMENT CO.,ITD
1
1.總述
本技術(shù)協(xié)議適用于 STM 公司新建巖棉線集棉機(jī)及固化爐工藝段煙氣酚醛樹脂、巖棉
纖維塵超低排放治理工程等離子導(dǎo)濾器項(xiàng)目。
等離子導(dǎo)濾器由導(dǎo)濾段、等離子段組成。煙氣流入導(dǎo)濾段,導(dǎo)濾段對(duì)煙氣進(jìn)行噴淋
水洗,將廢氣中的巖棉纖維塵和酚醛樹脂進(jìn)行初步清洗,另將廢氣中極其微小粒徑的水
溶性酚醛樹脂聚水凝結(jié)成較大粒徑的液滴狀態(tài),利于等離子體段對(duì)其分解、荷電并收集。
廢氣經(jīng)過導(dǎo)濾段預(yù)處理后進(jìn)入等離子段,廢氣中的酚醛樹脂、巖棉纖維、粉塵、液態(tài)水、
含水溶性酚醛樹脂的液滴經(jīng)等離子體分解和荷電后收集,有效降低煙氣中的異味。
等離子導(dǎo)濾器采用地面布置,等離子段布置于導(dǎo)濾段頂部,凈化處理后的煙氣經(jīng)等
離子導(dǎo)濾器頂部煙囪直排。
2.等離子導(dǎo)濾器設(shè)計(jì)條件
需方提供給供方等離子導(dǎo)濾器主要設(shè)計(jì)參數(shù):
序號(hào) 項(xiàng)目名稱 單位 數(shù)值 備注
1 煙氣量 m3
/h 300000 工況、濕態(tài)
2 煙氣溫度 ℃ ≤50 3 噴淋工藝 采用導(dǎo)濾段
4 等離子導(dǎo)濾器入口粉塵含量 mg/Nm3 ≤50 標(biāo)態(tài)、干基
5 等離子導(dǎo)濾器出口粉塵含量 mg/Nm3 ≤5 標(biāo)態(tài)、干基
3.標(biāo)準(zhǔn)和規(guī)范
等離子導(dǎo)濾器的制造、安裝、驗(yàn)收符合現(xiàn)行通用的國際和國家有關(guān)標(biāo)準(zhǔn),并且同時(shí)
滿足和參照以下標(biāo)準(zhǔn)和規(guī)范:
電氣裝置安裝工程施工及驗(yàn)收規(guī)范 GB50150
高壓靜電除塵用整流設(shè)備 JB/T9688-1999
高壓靜電除塵用整流設(shè)備試驗(yàn)方法 JB/T5845-1991
鋼結(jié)構(gòu)設(shè)計(jì)規(guī)范 GB50017-2003
襄陽九鼎昊天環(huán)保設(shè)備有限公司
XIANGYANG JIUDING HAOTIAN EP EQUIPMENT CO.,ITD
2
建筑抗震設(shè)計(jì)規(guī)范 GB50011-2001
固定式工業(yè)鋼平臺(tái) GB4053.4
工業(yè)企業(yè)噪聲控制設(shè)計(jì)規(guī)范 GBJ87-85
普通碳素結(jié)構(gòu)鋼和低合金結(jié)構(gòu)鋼熱軋厚鋼板及鋼帶 GB/T 3274-1988
優(yōu)質(zhì)碳素結(jié)構(gòu)鋼 GB/T 699-1999
煙風(fēng)煤粉管道零部件典型設(shè)計(jì)手冊(cè) D-LD2000
上述標(biāo)準(zhǔn)有矛盾時(shí),按較高標(biāo)準(zhǔn)執(zhí)行。
4.等離子導(dǎo)濾器要求
4.1 一般性要求
4.1.1 等離子導(dǎo)濾器(PFGF)采用地面布置。等離子導(dǎo)濾器的陽極(集塵極)為蜂窩式,
材質(zhì)采用 304 不銹鋼。外殼為碳鋼+外防腐。
4.1.2 等離子導(dǎo)濾器包括:殼體、陽極系統(tǒng)、陰極系統(tǒng)、煙氣均布系統(tǒng)、沖洗系統(tǒng)、接
地系統(tǒng)、高低壓供電及電源等電氣系統(tǒng)、平臺(tái)扶梯等裝置。
4.1.3 等離子導(dǎo)濾器進(jìn)口配備煙氣均布系統(tǒng),以便煙氣均勻地流過電場,煙氣均布系統(tǒng)
滿足等離子段濕煙氣運(yùn)行環(huán)境要求。
4.1.4 平臺(tái)扶梯設(shè)計(jì)要求
設(shè)備本體上所有需要維護(hù)、檢修、操作的地方均設(shè)置平臺(tái)和扶梯。平臺(tái)鋪板采用花
紋板 4mm 制作。
2021.11.30